A+++ & Wi-Fi Ready for energy saving. High Performance Omnia Plus series with great price

  • Comfort & Energy Savings thanks to smart Wi-Fi control
  • Energy class A+++ for ideal operation and even greater energy savings
  • High Density Air Dust Filter for 40% more dust absorption
  • Superpower Ionizer for clean and healthy atmosphere in your place
  • Ideal hygiene in your place thanks to Triple Action Filter & HEPA Filter

Become an Inventor Partner

  • O2MVI - 09WiFiR / O2MVO - 09
  • Cooling Capacity 9.000 Btu / h
  • Heating Capacity 10.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (3.500-11.000) Btu / h
  • Cooling Capacity Range 2.64 (1.02-3.22) kWatt
  • Heating Capacity (2.800-11.500) Btu / h
  • Heating Capacity 2.93 (0.82-3.37) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A++
  • SEER 6.2
  • Energy Consumption 147 kWh / year
  • Heating Middle Zone
  • Pdesign 2.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 770 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 2.8 kW
  • SCOP 5.1
  • Energy Consumption 769 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.8 (0.4 - 5.4) Α
  • Current Input Heating 3.9 (0.5 - 5.2) Α
  • Power Input Cooling 879 (100 - 1.240) W
  • Power Input Heating 887 (120 - 1.200) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 22.5 / 27 / 34 / 40 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    420 / 320 / 270 m³ / h
  • Sound Power Level Outdoor Unit 55.5 db(A)
  • Sound Power Level Indoor Unit 52 db(A)
  • Sound Power Level Outdoor Unit 60 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 3/8"
  • Power Supply Wire OUtdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    715 × 194 × 285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770 × 300 × 555 mm
  • Net Weight Indoor / Outdoor 6.8 / 25.2 kg
  • Refrigerant R410A / 800g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 12WiFiR / O2MVO - 12
  • Cooling Capacity 12.000 Btu / h
  • Heating Capacity 13.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (3.700-14.000) Btu / h
  • Cooling Capacity Range 3.52 (1.08-4.10) kWatt
  • Heating Capacity (3.000-14.400) Btu / h
  • Heating Capacity 3.81 (0.87-4.22) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 201 kWh / year
  • Heating Middle Zone
  • Pdesign 2.3 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 805 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 2.9 kW
  • SCOP 5.1
  • Energy Consumption 796 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 5.5 (0.4 - 6.9) Α
  • Current Input Heating 5.0 (0.6 - 6.6) Α
  • Power Input Cooling 1.256(100-1.580) W
  • Power Input Heating 1.154(130-1.510) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 23 / 28 / 36 / 41 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    570 / 470/ 370 m³ / h
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 53 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 3/8"
  • Power Supply Wire OUtdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    805 × 194 × 285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770 × 300 × 555 mm
  • Net Weight Indoor / Outdoor 7.2 / 25.5 kg
  • Refrigerant R410A / 800g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 18WiFiR / O2MVO - 18
  • Cooling Capacity 18.000 Btu / h
  • Heating Capacity 19.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (6.200-20.900) Btu / h
  • Cooling Capacity Range 5.28 (1.81-6.13) kWatt
  • Heating Capacity (4.700-23.000) Btu / h
  • Heating Capacity 5.57 (1.37-6.74) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 6.4
  • Energy Consumption 290 kWh / year
  • Heating Middle Zone
  • Pdesign 4.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1,470 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 4.4 kW
  • SCOP 5.1
  • Energy Consumption 1,208 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.1 (0.6 - 10.3) Α
  • Current Input Heating 6.7 (0.9 - 10.5) Α
  • Power Input Cooling 1.633(140-2.360) W
  • Power Input Heating 1.542(200-2.410) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 25 / 35 / 40 / 47 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    840 / 680 / 540 m³ / h
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 56 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 1/2"
  • Power Supply Wire OUtdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    957 × 213 × 302 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800 × 333 × 554 mm
  • Net Weight Indoor / Outdoor 9.5 / 37.8 kg
  • Refrigerant R410A / 1.480g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 24WiFiR / O2MVO - 24
  • Cooling Capacity 24.000 Btu / h
  • Heating Capacity 25.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (9.100-26.900) Btu / h
  • Cooling Capacity Range 7.03 (2.66-7.88) kWatt
  • Heating Capacity (5.500-30.000) Btu / h
  • Heating Capacity 7.33 (1.61-8.79) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 7.0 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 402 kWh / year
  • Heating Middle Zone
  • Pdesign 5.4 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1,890 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 6.3 kW
  • SCOP 5.1
  • Energy Consumption 1,729 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 11.7 (1.0 - 13.2) Α
  • Current Input Heating 11.1 (1.1 - 13.7) Α
  • Power Input Cooling 2.684(240-3.030) W
  • Power Input Heating 2.549(260-3.140) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 27 / 34 / 39 / 45 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    980 / 800 / 640 m³ / h
  • Sound Power Level Outdoor Unit 60 db(A)
  • Sound Power Level Indoor Unit 59 db(A)
  • Sound Power Level Outdoor Unit 65 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 3 / 8" / 5/8"
  • Power Supply Wire OUtdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.040×220×327 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    845 × 363 × 702 mm
  • Net Weight Indoor / Outdoor 11.9 / 48.4 kg
  • Refrigerant R410A / 1.850g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C

Wilt u het geluid en de display uitschakelen? Door de gedempte modus te activeren zorgt uw airconditioner ervoor dat u een stille en comfortabele nacht tegemoet gaat.

Gedempte Modus

Het elimineert ongewenst vocht in de binnenunit na de koeling modus. Na het uitschakelen van de airconditioner zal de ventilator van de binnenunit enige tijd blijven draaien om de binnenunit te drogen.

Krachtige Zelfreiniging

Zodra zich een abnormale werking voordoet of onderdelen falen, zal de unit automatisch uitgeschakeld worden om het systeem te beschermen. Ondertussen zal er een beschermings- of errorcode aangegeven zodat er snel kan worden vastgesteld wat de oorzaak is.

Zodra de unit ingeschakeld wordt beweegt de horizontale lamel automatisch naar dezelfde positie als hoe deze stond bij het uitschakelen.

De binnenunit zal errorcode “EC” weergeven en automatisch stoppen als er een lekkage in het koudemiddel gedetecteerd is.

Door de plaatsing van de sensor kan de waargenomen temperatuur van de binnenunit sensor afwijken van de werkelijke temperatuur van de ruimte. Dankzij deze functie kunt u het verschil minimaliseren en betere omstandigheden bereiken in uw ruimte.

Zowel de linker- als rechterkant van de binnenunit hebben een aansluiting voor condenswater afvoer voor flexibele installatie.

Het stroomverbruik in de StandBy-stand is slechts 1,0 W. Dit zorgt voor een hogere energiebesparing.

De ventilatorsnelheid wordt automatisch geregeld van de laagste stand tot de ingestelde stand in verhouding met de verdampingstemperatuur zodra de unit begint met het verwarmingsprogramma.

Als de temperatuursensor error voorkomt zal de airconditioner de code weergeven en onmiddellijk stoppen. Indien de werking van de installatie dringend gewenst kan deze in noodbedrijf gezet worden. Om te voorkomen dat de airconditioner zichzelf in urgente situaties uitschakelt is er de noodgevallen modus.

Verdeelt koele en warme lucht over een maximale oppervlakte door de horizontale lamellen automatisch in de optimale stand te zetten.

De ventilator motoren van de binnen- en buitenunit, evenals de compressor, zijn opgewaardeerd naar de All DC Inverter technologie. Op deze manier kunnen de compressor en ventilatoren de capaciteit afhankelijk van de behoeften van de gebruiker en de omstandigheden nagenoeg traploos aanpassen waarmee een optimaal comfort en een minimaal energieverbruik gewaarborgd wordt.

Stel de unit in om automatisch te starten en stoppen binnen een periode van 24 uur.

Deze functie geeft tijdelijk een boost in het koel- en verwarmvermogen om de kamer snel af te koelen of op te warmen.

Wanneer de airconditioner stopt als gevolg van een stroomstoring zal de airconditioner automatisch herstarten en de oorspronkelijke instellingen worden hervat nadat de elektrische voeding is hersteld.

Tot 12 ventilatorsnelheid standen zorgen voor een nauwkeurige controle en brengt een comfortabelere luchtstroom.

Door de DC ventilator motor is het aantal snelheden toegenomen van 2 naar 5 standen. Dit zorgt voor meer comfort en efficiënte werking.

Media Library for Omnia air conditioners

User, Remote Control & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos

Find more

All you need to know about