Life Pro air conditioner with A+++ energy class and new ecological refrigerant R32

  • Reduced maintenance costs thanks to the new refrigerant R32
  • A+++ for maximum energy savings
  • Effective absorption of more than 90% of bacteria
  • Stable operation in hard environmental conditions
  • Ideal conditions wherever you want thanks to the Follow Me mode

Become an Inventor Partner

  • L4VI32 - 09 /L4VO32 - 09
  • Cooling Capacity 9.000 Btu / h
  • Heating Capacity 9.554 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (1.700-11.500) Btu / h
  • Cooling Capacity Range 2.49(0.49-3.37) kWatt
  • Heating Capacity (1.700-12.000) Btu / h
  • Heating Capacity 2.80(0.49-3.52) kWatt
  • Seasonal Efficiency
    (In accordance to EN14825)
  • Cooling
  • Pdesign 2.5 kW
  • Energy Class A++
  • SEER 6.1
  • Annual Energy Consumption 143 kWh / year
  • Heating Middle Zone
  • Pdesign 2.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Annual Energy Consumption 910 kWh / year
  • Heating Warm Zone
  • Pdesign 2.8 kW
  • Energy Class A+++
  • SCOP 5.1
  • Annual Energy Consumption 769 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.9 (0.7 - 6.2) Α
  • Current Input Heating 3.4 (0.8 - 6.7) Α
  • Power Input Cooling 805 (160 - 1.400) W
  • Power Input Heating 755 (200 - 1.500) W
  • Air Flow Volume 560 / 490 / 430 / 330 m³ / h
  • Noise Level
    Indoor Unit
    28 / 32 / 36 / 39 dB(A)
  • Noise Level
    Outdoor Unit
    52 db(A)
  • Sound Power Level
    Indoor Unit
    55 db(A)
  • Sound Power Level
    Outdoor Unit
    61 db(A)
  • Compressor Type ROTARY
  • Liquid / Gas line 1 / 4" / 3/8"
  • Power supply cables
    outdor unit
    3 × 1.5 / 10 Α
  • Communication cables 4 × 1.5 No x mm²
  • Dimensions Indoor Unit
    (WxDxH)
    790 × 200 × 275 mm
  • Dimensions Outdoor Unit
    (WxDxH)
    776 × 320 × 540 mm
  • Net Weight
    Indoor/Outdoor Unit
    9.0 / 29.5 kg
  • Refrigerant R32 / 600g
  • Range Cooling (Outdoor) -15 - 43 °C
  • Range Heating (Outdoor) -15 - 24 °C
  • L4VI32 - 12 / L4VO32 - 12
  • Cooling Capacity 12.000 Btu / h
  • Heating Capacity 11.942 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (2.047-12.965) Btu / h
  • Cooling Capacity Range 3.20(0.59-3.80) kWatt
  • Heating Capacity (2.047-12.966) Btu / h
  • Heating Capacity 3.50(0.59-3.80) kWatt
  • Seasonal Efficiency
    (In accordance to EN14825)
  • Cooling
  • Pdesign 3.2 kW
  • Energy Class A++
  • SEER 6.1
  • Annual Energy Consumption 184 kWh / year
  • Heating Middle Zone
  • Pdesign 3.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Annual Energy Consumption 1,120 kWh / year
  • Heating Warm Zone
  • Pdesign 3.4 kW
  • Energy Class A+++
  • SCOP 5.1
  • Annual Energy Consumption 933 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 4.4 (0.5 - 6.2) Α
  • Current Input Heating 4.3 (0.5 - 6.7) Α
  • Power Input Cooling 997 (120 - 1.400) W
  • Power Input Heating 970 (120 - 1.500) W
  • Air Flow Volume 560 / 480 / 410 / 290 m³ / h
  • Noise Level
    Indoor Unit
    28 / 34 / 37 / 42 dB(A)
  • Noise Level
    Outdoor Unit
    52 db(A)
  • Sound Power Level
    Indoor Unit
    55 db(A)
  • Sound Power Level
    Outdoor Unit
    62 db(A)
  • Compressor Type ROTARY
  • Liquid / Gas line 1 / 4" / 3/8"
  • Power supply cables
    outdor unit
    3 × 1.5 / 10 Α
  • Communication cables 4 × 1.5 No x mm²
  • Dimensions Indoor Unit
    (WxDxH)
    790 × 200 × 275 mm
  • Dimensions Outdoor Unit
    (WxDxH)
    848 × 320 × 596 mm
  • Net Weight
    Indoor/Outdoor Unit
    9.0 / 31 kg
  • Refrigerant R32 / 590g
  • Range Cooling (Outdoor) -15 - 43 °C
  • Range Heating (Outdoor) -15 - 24 °C
  • L4VI32 - 16 / L4VO32 - 16
  • Cooling Capacity 16.000 Btu / h
  • Heating Capacity 17.742 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (2.218-17.742) Btu / h
  • Cooling Capacity Range 4.60(0.65-5.20) kWatt
  • Heating Capacity (2.388-18.425) Btu / h
  • Heating Capacity 5.20(0.69-5.40) kWatt
  • Seasonal Efficiency
    (In accordance to EN14825)
  • Cooling
  • Pdesign 4.6 kW
  • Energy Class A++
  • SEER 6.1
  • Annual Energy Consumption 264 kWh / year
  • Heating Middle Zone
  • Pdesign 3.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Annual Energy Consumption 1,260 kWh / year
  • Heating Warm Zone
  • Pdesign 3.6 kW
  • Energy Class A+++
  • SCOP 5.1
  • Annual Energy Consumption 988 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 6.3 (1.4 - 8.0) Α
  • Current Input Heating 6.2 (1.4 - 8.0) Α
  • Power Input Cooling 1.430 (150 - 1.700) W
  • Power Input Heating 1.400 (160 - 1.600) W
  • Air Flow Volume 850 / 720 / 610 / 520 m³ / h
  • Noise Level
    Indoor Unit
    34 / 39 / 44 / 48 dB(A)
  • Noise Level
    Outdoor Unit
    54 db(A)
  • Sound Power Level
    Indoor Unit
    58 db(A)
  • Sound Power Level
    Outdoor Unit
    63 db(A)
  • Compressor Type ROTARY
  • Liquid / Gas line 1 / 4" / 3/8"
  • Power supply cables
    outdor unit
    3 × 2.5 / 16 Α
  • Communication cables 4 × 1.5 No x mm²
  • Dimensions Indoor Unit
    (WxDxH)
    970 × 224 × 300 mm
  • Dimensions Outdoor Unit
    (WxDxH)
    842 × 320 × 596 mm
  • Net Weight
    Indoor/Outdoor Unit
    13.5 / 34 kg
  • Refrigerant R32 / 770g
  • Range Cooling (Outdoor) -15 - 43 °C
  • Range Heating (Outdoor) -15 - 24 °C
  • L4VI32 - 18 / L4VO32 - 18
  • Cooling Capacity 18.000 Btu / h
  • Heating Capacity 18.015 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (4.094-21.154) Btu / h
  • Cooling Capacity Range 5.13(1.19-6.20) kWatt
  • Heating Capacity (4.094-22.519) Btu / h
  • Heating Capacity 5.28(1.19-6.60) kWatt
  • Seasonal Efficiency
    (In accordance to EN14825)
  • Cooling
  • Pdesign 5.1 kW
  • Energy Class A++
  • SEER 6.1
  • Annual Energy Consumption 293 kWh / year
  • Heating Middle Zone
  • Pdesign 4.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Annual Energy Consumption 1,470 kWh / year
  • Heating Warm Zone
  • Pdesign 4.3 kW
  • Energy Class A+++
  • SCOP 5.1
  • Annual Energy Consumption 1,180 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.0 (0.9 - 10.8) Α
  • Current Input Heating 6.3 (2.0 - 12.0) Α
  • Power Input Cooling 1.580 (350 - 2.100) W
  • Power Input Heating 1.420 (350 - 2.300) W
  • Air Flow Volume 850 / 720 / 610 / 520 m³ / h
  • Noise Level
    Indoor Unit
    34 / 39 / 44 / 49 dB(A)
  • Noise Level
    Outdoor Unit
    56 db(A)
  • Sound Power Level
    Indoor Unit
    59 db(A)
  • Sound Power Level
    Outdoor Unit
    64 db(A)
  • Compressor Type ROTARY
  • Liquid / Gas line 1 / 4" / 1/2"
  • Power supply cables
    outdor unit
    3 × 2.5 / 16 Α
  • Communication cables 4 × 1.5 No x mm²
  • Dimensions Indoor Unit
    (WxDxH)
    970 × 224 × 300 mm
  • Dimensions Outdoor Unit
    (WxDxH)
    899 × 378 × 596 mm
  • Net Weight
    Indoor/Outdoor Unit
    13.5 / 39 kg
  • Refrigerant R32 / 900g
  • Range Cooling (Outdoor) -15 - 43 °C
  • Range Heating (Outdoor) -15 - 24 °C
  • L4VI32 - 24 / L4VO32 - 24
  • Cooling Capacity 24.000 Btu / h
  • Heating Capacity 22.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (6.800-28.000) Btu / h
  • Cooling Capacity Range 6.45(1.99-8.21) kWatt
  • Heating Capacity (6.800-29.000) Btu / h
  • Heating Capacity 6.44(1.99-8.50) kWatt
  • Seasonal Efficiency
    (In accordance to EN14825)
  • Cooling
  • Pdesign 6.4 kW
  • Energy Class A++
  • SEER 6.3
  • Annual Energy Consumption 356 kWh / year
  • Heating Middle Zone
  • Pdesign 6.3 kW
  • Energy Class A+
  • SCOP 4.0
  • Annual Energy Consumption 2,205 kWh / year
  • Heating Warm Zone
  • Pdesign 6.4 kW
  • Energy Class A+++
  • SCOP 5.1
  • Annual Energy Consumption 1,757 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 8.4 (2.5 - 13.0) Α
  • Current Input Heating 8.0 (2.5 - 13.5) Α
  • Power Input Cooling 1.950 (400 - 3.000) W
  • Power Input Heating 1.735 (450 - 3.100) W
  • Air Flow Volume 1.250 / 1.050 / 950 / 850 m³ / h
  • Noise Level
    Indoor Unit
    39 / 41 / 44 / 49 dB(A)
  • Noise Level
    Outdoor Unit
    58 db(A)
  • Sound Power Level
    Indoor Unit
    63 db(A)
  • Sound Power Level
    Outdoor Unit
    68 db(A)
  • Compressor Type ROTARY
  • Liquid / Gas line 1 / 4" / 5/8"
  • Power supply cables
    outdor unit
    3 × 2.5 / 16 Α
  • Communication cables 4 × 1.5 No x mm²
  • Dimensions Indoor Unit
    (WxDxH)
    1.078 × 246 × 325 mm
  • Dimensions Outdoor Unit
    (WxDxH)
    955 × 396 × 700 mm
  • Net Weight
    Indoor/Outdoor Unit
    16.5 / 52.5 kg
  • Refrigerant R32 / 1.700g
  • Range Cooling (Outdoor) -15 - 43 °C
  • Range Heating (Outdoor) -15 - 24 °C

Voorkom mogelijke beschadigingen door het weer op plekken waar er niet verwarmd wordt en voorkom de risico’s gedurende de winter. Schakel de 8°C functie in en de airconditioner zal slechts waar nodig verwarmen om een stabiele kamertemperatuur van 8°C te behouden.

Met deze Slaap Modus stelt de airconditioner de kamertemperatuur in voor perfecte slaap omstandigheden met een minimaal geluidsniveau en een grote energiebesparing.

Zowel de linker- als rechterkant van de binnenunit hebben een aansluiting voor condenswater afvoer voor flexibele installatie.

De binnenunit zal errorcode “EC” weergeven en automatisch stoppen als er een lekkage in het koudemiddel gedetecteerd is.

Zowel de linker- als rechterkant van de binnenunit hebben een aansluiting voor condenswater afvoer voor flexibele installatie.

De ventilatorsnelheid wordt automatisch geregeld van de laagste stand tot de ingestelde stand in verhouding met de verdampingstemperatuur zodra de unit begint met het verwarmingsprogramma.

Stel de unit in om automatisch te starten en stoppen binnen een periode van 24 uur.

Wanneer de airconditioner stopt als gevolg van een stroomstoring zal de airconditioner automatisch herstarten en de oorspronkelijke instellingen worden hervat nadat de elektrische voeding is hersteld.

Deze functie geeft tijdelijk een boost in het koel- en verwarmvermogen om de kamer snel af te koelen of op te warmen.

Media Library for Life Pro air conditioners

User, Remote Control & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …